Welcome to the world of smart home

0
Model No: STBART0200K

Schneider STBART0200K standard analog input kit STB - 2 I - 15 bits + sign

Part number : STBART0200K standard analog input kit STB - 2 I - 15 bits + sign
Faster quote : saleszxtech@163.com
minimum order :
1 piece
Supply Ability :
1000piece / Day
Stock Time :
2-3Day
Quantity :
add to cart
Contact Now

Specifications

Main
Range of productModicon STB distributed I/O solution
Product or component typeStandard analog input kit
kit compositionSTBART0200 module
STBXTS1100, 6-terminal screw type connector
STBXBA1000 base
STBXTS2100, 6-terminal spring clamp connector
Analogue input typeVoltage +/- 80 mV
Temperature probe -100...+260 °C Cu 10 2, 3 or 4 wires IEC
Temperature probe -100...+450 °C Pt 100 2, 3 or 4 wires US/JIS
Temperature probe -100...+450 °C Pt 1000 2, 3 or 4 wires US/JIS
Temperature probe -200...+850 °C Pt 100 2, 3 or 4 wires IEC
Temperature probe -200...+850 °C Pt 1000 2, 3 or 4 wires IEC
Temperature probe -60...+180 °C Ni 100 2, 3 or 4 wires IEC
Temperature probe -60...+180 °C Ni 1000 2, 3 or 4 wires IEC
Thermocouple +130...+1820 °C thermocouple B
Thermocouple -200...+760 °C thermocouple J
Thermocouple -270...+1000 °C thermocouple E
Thermocouple -270...+1370 °C thermocouple K
Thermocouple -270...+400 °C thermocouple T
Thermocouple -50...+1665 °C thermocouple R
Thermocouple -50...+1665 °C thermocouple S
Analogue input number2
Analogue input resolution15 bits + sign
Type of filterSingle low pass input filter 25 Hz

Complementary
Absolute maximum input+/- 7.5 V DC
Cold swappingYes
Hot swapping fallbackYes for standard NIMs
Fallback statusState 0 basic NIMs
User configurable standard NIMs
Data formatEN 61131-2
IEC 61131-2
Input impedance10 MOhm +/- 80 mV
Maximum supply current for sensors100 mA per input channels
Protection typeShort-circuit protection
Absolute accuracy error+/- 0.1 % of full scale 25 °C internal
+/- 0.15 % of full scale 25 °C external
Insulation between channels and logic bus1500 V for 1 minute
Addressing requirement1 word for cold-junction compensation
2 input words
Product compatibilityMounting base STBXBA1000
Power distribution module STBPDT3100/3105
[Us] rated supply voltage24 V DC
SupplyPower distribution module
Current consumption30 mA at 5 V DC for logic bus
Measurement resolution0.01 mV voltage
0.1 °C or 0.1 °F temperature probe
0.1 °C or 0.1 °F thermocouple
Conversion time150 ms voltage 60 Hz
170 ms voltage 50 Hz
180 ms temperature probe 60 Hz 2 or 4 wires
200 ms temperature probe 50 Hz 2 or 4 wires
210 ms thermocouple with internal cold-junction compensation 60 Hz
230 ms thermocouple with internal cold-junction compensation 50 Hz
300 ms temperature probe 60 Hz 3 wires
340 ms temperature probe 50 Hz 3 wires
360 ms thermocouple with external cold-junction compensation 60 Hz
400 ms thermocouple with external cold-junction compensation 50 Hz
Maximum wiring resistance20 Ohm Cu 10 IEC/US/JIS 2 or 3 wires
20 Ohm Ni 100 IEC/US/JIS 2 or 3 wires
20 Ohm Pt 100 IEC/US/JIS 2 or 3 wires
200 Ohm Ni 1000 IEC/US/JIS 2 or 3 wires
200 Ohm Pt 1000 IEC/US/JIS 2 or 3 wires
50 Ohm Cu 10 IEC/US/JIS 4 wires
50 Ohm Ni 100 IEC/US/JIS 4 wires
50 Ohm Pt 100 IEC/US/JIS 4 wires
500 Ohm Ni 1000 IEC/US/JIS 4 wires
500 Ohm Pt 1000 IEC/US/JIS 4 wires
Measurement accuracy+/- 1 °C Ni 100 25 °C external
+/- 1 °C Ni 100 25 °C internal
+/- 1 °C Ni 1000 25 °C external
+/- 1 °C Ni 1000 25 °C internal
+/- 1 °C Pt 100 25 °C internal
+/- 1 °C Pt 1000 25 °C internal
+/- 1.75 °C thermocouple B with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple E with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple J with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple K with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple R with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple S with external cold-junction compensation 25 °C
+/- 1.75 °C thermocouple T with external cold-junction compensation 25 °C
+/- 2 °C Pt 100 25 °C external
+/- 2 °C Pt 1000 25 °C external
+/- 2.85 °C thermocouple B with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple E with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple J with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple K with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple R with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple S with external cold-junction compensation 60 °C
+/- 2.85 °C thermocouple T with external cold-junction compensation 60 °C
+/- 3.6 °C thermocouple R with internal cold-junction compensation 25 °C
+/- 4 °C Cu 10 25 °C external
+/- 4 °C Cu 10 25 °C internal
+/- 4 °C thermocouple K with internal cold-junction compensation 25 °C
+/- 4.1 °C thermocouple S with internal cold-junction compensation 25 °C
+/- 4.2 °C thermocouple R with internal cold-junction compensation 60 °C
+/- 4.4 °C thermocouple T with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple B with internal cold-junction compensation 25 °C
+/- 4.6 °C thermocouple E with internal cold-junction compensation 25 °C
+/- 5 °C thermocouple S with internal cold-junction compensation 60 °C
+/- 5.1 °C thermocouple J with internal cold-junction compensation 25 °C
+/- 5.5 °C thermocouple K with internal cold-junction compensation 60 °C
+/- 6.4 °C thermocouple T with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple B with internal cold-junction compensation 60 °C
+/- 6.8 °C thermocouple E with internal cold-junction compensation 60 °C
+/- 7 °C thermocouple J with internal cold-junction compensation 60 °C
MarkingCE
Overvoltage categoryII
Status LED1 LED (green) module status (RDY)
1 LED (red) module error (ERR)
Environment
Product certificationsUL
FM Class 1 Division 2
CSA
ATEX Cat 3G
C-Tick
Pollution degree2 conforming to IEC 60664-1
Operating altitude<= 2000 m
IP degree of protectionIP20 conforming to EN 61131-2 class 1
Ambient air temperature for operation0…70 °C
Ambient air temperature for operation32...140 °F without derating
Ambient air temperature for storage-40…85 °C without derating
Ambient air temperature for storage-40...185 °F without derating
Relative humidity95 % at 60 °C without condensation
Vibration resistance+/-0.35 mm at 10…58 Hz
3 gn at 58…150 Hz on 35 x 7.5 mm symmetrical DIN rail
5 gn at 58…150 Hz on 35 x 15 mm symmetrical DIN rail
Shock resistance30 gn for 11 ms conforming to IEC 88 reference 2-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height3.000 cm
Package 1 Width8.300 cm
Package 1 Length13.300 cm
Package 1 Weight136.000 g
Unit Type of Package 2S02
Number of Units in Package 242
Package 2 Height15.000 cm
Package 2 Width30.000 cm
Package 2 Length40.000 cm
Package 2 Weight6.031 kg

Lead time: in stock

Warranty: 12 months

100% Payment in Advance
Courier partners: DHL, UPS, FedEx 

Packing & Delivery

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging.

Related parts :

CompactCom B30
DeviceNet™ B30 Brick  AB6381
Profibus DPV1 B30 Brick AB6380

EtherCAT B30 Brick AB6385

EtherNet/IP™ 2 Port B30 Brick AB6384
Modbus TCP 2 Port B30 Brick AB6383
PROFINET IO 2 Port B30 Brick AB6382

Anybus CompactCom M30 MODULE

Questions? Call/Whatsapp +86-18030186862 or email saleszxtech@163.com

We specialize in purchasing and selling quality pre-owned mechanical parts, PLCs, motors, panel views, electrical components and other industrial surplus inventory. We stock a wide variety of items ranging from small parts to complete machines. Whether you are interested in selling or buying, we make it our mission to help customers have a quick, hassle-free experience.