Specifications

Main
Range of ProductModicon M221
Product or Component TypeLogic controller
[Us] rated supply voltage24 V DC
Discrete input number8, discrete input IEC 61131-2 Type 1
Analogue input number2 0...10 V
Discrete output typeRelay normally open
Discrete output number8 relay
Discrete output voltage5...125 V DC
5...250 V AC
Discrete output current2 A

Complementary
Discrete I/O number16
Maximum number of I/O expansion module7 (local I/O-Architecture)
14 (remote I/O-Architecture)
Supply voltage limits20.4…28.8 V
Inrush current35 A
Maximum power consumption in W23.3 W 24 V with max number of I/O expansion module)
4.3 W 24 V without I/O expansion module)
Power supply output current0.52 A 5 V expansion bus
0.46 A 24 V expansion bus
Discrete input logicSink or source (positive/negative)
Discrete input voltage24 V
Discrete input voltage typeDC
Analogue input resolution10 bits
LSB value10 mV
Conversion time1 ms per channel + 1 controller cycle time analog input
Permitted overload on inputs+/- 30 V DC 5 min maximum)analog input
+/- 13 V DC permanent)analog input
Voltage state 1 guaranteed>= 15 V input
Voltage state 0 guaranteed<= 5 V input
Discrete input current7 mA discrete input
5 mA fast input
Input impedance100 kOhm analog input
3.4 kOhm input
4.9 kOhm fast input
Response time35 µs turn-off, I2...I5 input
5 µs turn-on, I0, I1, I6, I7 fast input
35 µs turn-on, other terminals input
5 µs turn-off, I0, I1, I6, I7 fast input
100 µs turn-off, other terminals input
5 µs turn-on, turn-off, Q0...Q1 output
50 µs turn-on, turn-off, Q2...Q3 output
300 µs turn-on, turn-off, other terminals output
Configurable filtering time0 ms input
3 ms input
12 ms input
Output voltage limits125 V DC
277 V AC
Maximum current per output common7 A
Absolute accuracy error+/- 1 % of full scale analog input
Electrical durability100000 cycles AC-12, 120 V, 240 VA, resistive
100000 cycles AC-12, 240 V, 480 VA, resistive
300000 cycles AC-12, 120 V, 80 VA, resistive
300000 cycles AC-12, 240 V, 160 VA, resistive
100000 cycles AC-15, cos phi = 0.35, 120 V, 60 VA, inductive
100000 cycles AC-15, cos phi = 0.35, 240 V, 120 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 120 V, 18 VA, inductive
300000 cycles AC-15, cos phi = 0.35, 240 V, 36 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 120 V, 120 VA, inductive
100000 cycles AC-14, cos phi = 0.7, 240 V, 240 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 120 V, 36 VA, inductive
300000 cycles AC-14, cos phi = 0.7, 240 V, 72 VA, inductive
100000 cycles DC-12, 24 V, 48 W, resistive
300000 cycles DC-12, 24 V, 16 W, resistive
100000 cycles DC-13, 24 V, 24 W, inductive (L/R = 7 ms)
300000 cycles DC-13, 24 V, 7.2 W, inductive (L/R = 7 ms)
Switching frequency20 switching operations/minute with maximum load
Mechanical durability20000000 cycles relay output
Minimum load1 mA 5 V DC relay output
Protection typeWithout protection 5 A
Reset time1 s
Memory capacity256 kB user application and data RAM 10000 instructions
256 kB internal variables RAM
Data backed up256 kB built-in flash memory backup of application and data
Data storage equipment2 GB SD card optional)
Battery typeBR2032 lithium non-rechargeable 4 year(s)
Backup time1 year 77 °F (25 °C) by interruption of power supply)
Execution time for 1 KInstruction0.3 ms event and periodic task
0.7 ms other instruction
Execution time per instruction0.2 µs Boolean
Exct time for event task60 µs response time
Application structure1 configurable freewheeling/cyclic master task
1 cyclic auxiliary task
8 interrupt tasks
Maximum size of object areas512 %KW constant words
255 %C counters
8000 %MW memory words
255 %TM timers
512 %M memory bits
Realtime clockWith
Clock drift<= 30 s/month 77 °F (25 °C)
Regulation loopAdjustable PID regulator up to 14 simultaneous loops
Function AvailableFrequency generator
PWM
PLS
Counting input number4 fast input (HSC mode) 100 kHz 32 bits
counter functionSingle phase
A/B
Pulse/direction
Integrated connection typeUSB port mini B USB 2.0
Non isolated serial link serial 1 RJ45 RS232/RS485
Ethernet RJ45
SupplySerial 1)serial link supply 5 V, <200 mA
Transmission rate1.2...115.2 kbit/s (115.2 kbit/s by default) 49.21 ft (15 m) RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) 9.84 ft (3 m) RS232
480 Mbit/s USB
Communication port protocolUSB port USB - SoMachine-Network
Non isolated serial link Modbus master/slave - RTU/ASCII or SoMachine-Network
Ethernet
Port Ethernet10BASE-T/100BASE-TX 1 328.08 ft (100 m) copper cable
Communication ServiceDHCP client
Modbus TCP slave device
Ethernet/IP adapter
Modbus TCP client
Modbus TCP server
Local signallingFor PWR 1 LED (green)
for RUN 1 LED (green)
for module error (ERR) 1 LED (red)
for SD card access (SD) 1 LED (green)
for BAT 1 LED (red)
for I/O state 1 LED per channel (green)
for SL 1 LED (green)
for ACT Ethernet network activity (green)
for Link (Link Status) Ethernet network link (yellow)
Electrical connectionTerminal block, 3 for connecting the 24 V DC power supply
connector, 4 for analogue inputs
Mini B USB 2.0 connector for a programming terminal
removable screw terminal block, 10 for inputs
removable screw terminal block, 11 for outputs
Maximum cable distance between devicesShielded cable <32.81 ft (10 m) fast input
Unshielded cable <98.43 ft (30 m) output
Unshielded cable <98.43 ft (30 m) digital input
Unshielded cable <3.28 ft (1 m) analog input
Shielded cable <9.84 ft (3 m) fast output
InsulationBetween input and internal logic 500 V AC
Between fast input and internal logic 500 V AC
Non-insulated between inputs
Between output and internal logic 500 V AC
Between output groups 500 V AC
Non-insulated between analogue input and internal logic
Non-insulated between analogue inputs
MarkingCE
Mounting supportTop hat type TH35-15 rail IEC 60715
Top hat type TH35-7.5 rail IEC 60715
plate or panel with fixing kit
Height3.54 in (90 mm)
Depth2.76 in (70 mm)
Width2.76 in (70 mm)
Product Weight0.58 lb(US) (0.264 kg)
Environment
StandardsEN/IEC 61010-2-201
EN/IEC 61131-2
EN/IEC 60664-1
Product CertificationsLR
cULus
CSA
DNV-GL
RCM
EAC
ABS
IACS E10
Environmental characteristicOrdinary and hazardous location
Resistance to electrostatic discharge8 kV in air EN/IEC 61000-4-2
4 kV on contact EN/IEC 61000-4-2
Resistance to electromagnetic fields9.14 V/m (10 V/m) 80 MHz...1 GHz EN/IEC 61000-4-3
2.74 V/m (3 V/m) 1.4 GHz...2 GHz EN/IEC 61000-4-3
0.91 V/m (1 V/m) 2...2.7 GHz EN/IEC 61000-4-3
Resistance to magnetic fields98.43 A/m (30 A/m) 50/60 Hz EN/IEC 61000-4-8
Resistance to fast transients2 kV EN/IEC 61000-4-4 power lines)
2 kV EN/IEC 61000-4-4 relay output)
1 kV EN/IEC 61000-4-4 I/O)
1 kV EN/IEC 61000-4-4 Ethernet line)
1 kV EN/IEC 61000-4-4 serial link)
Surge withstand2 kV power lines (AC) common mode EN/IEC 61000-4-5
2 kV relay output common mode EN/IEC 61000-4-5
1 kV I/O common mode EN/IEC 61000-4-5
1 kV shielded cable common mode EN/IEC 61000-4-5
0.5 kV power lines (DC) differential mode EN/IEC 61000-4-5
1 kV power lines (AC) differential mode EN/IEC 61000-4-5
1 kV relay output differential mode EN/IEC 61000-4-5
0.5 kV power lines (DC) common mode EN/IEC 61000-4-5
Resistance to conducted disturbances10 V 0.15...80 MHz EN/IEC 61000-4-6
3 V 0.1...80 MHz Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) Marine specification (LR, ABS, DNV, GL)
Electromagnetic emissionConducted emissions 79 dBμV/m QP/66 dBμV/m AV power lines (AC))0.15…0.5 MHz EN/IEC 55011
Conducted emissions 73 dBμV/m QP/60 dBμV/m AV power lines (AC))0.5…300 MHz EN/IEC 55011
Conducted emissions 120...69 dBµV/m QP power lines)10…150 kHz EN/IEC 55011
Conducted emissions 63 dBμV/m QP power lines)1.5…30 MHz EN/IEC 55011
Radiated emissions 40 dBμV/m QP class A 10 m)30…230 MHz EN/IEC 55011
Conducted emissions 79...63 dBμV/m QP power lines)150…1500 kHz EN/IEC 55011
Radiated emissions 47 dBμV/m QP class A 10 m)200…1000 MHz EN/IEC 55011
Immunity to microbreaks10 ms
Ambient air temperature for operation14…131 °F (-10…55 °C) horizontal installation)
14…95 °F (-10…35 °C) vertical installation)
Ambient Air Temperature for Storage-13…158 °F (-25…70 °C)
Relative humidity10…95 %, without condensation in operation)
10…95 %, without condensation in storage)
IP degree of protectionIP20 with protective cover in place
Pollution degree<= 2
Operating altitude0...6561.68 ft (0...2000 m)
Storage altitude0.00…9842.52 ft (0…3000 m)
Vibration resistance3.5 mm 5…8.4 Hz symmetrical rail
3.5 mm 5…8.4 Hz panel mounting
1 gn 8.4…150 Hz symmetrical rail
1 gn 8.4…150 Hz panel mounting
Shock resistance98 m/s² 11 ms
Ordering and shipping details
Category22533-M2XX PLC & ACCESSORIES
Discount ScheduleMSX
GTIN3606480611278
ReturnabilityYes
Country of originTW
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Height4.21 in (10.7 cm)
Package 1 Width5.04 in (12.8 cm)
Package 1 Length3.82 in (9.7 cm)
Package 1 Weight15.59 oz (442.0 g)
Unit Type of Package 2S04
Number of Units in Package 224
Package 2 Height11.81 in (30 cm)
Package 2 Width15.75 in (40 cm)
Package 2 Length23.62 in (60 cm)
Package 2 Weight25.13 lb(US) (11.398 kg)
Unit Type of Package 3P12
Number of Units in Package 3288
Package 3 Height41.34 in (105.0 cm)
Package 3 Width47.24 in (120.0 cm)
Package 3 Length31.50 in (80.0 cm)
Package 3 Weight313.06 lb(US) (142 kg)

Description

This TM221 controller is part of the Modicon M221 Logic controller range. It has 16 logic I/O and it is supplied with 24V dc. It is supplied with removable screw terminal blocks for connecting the I/O, a removable screw terminal block for connecting the power supply, a button cell backup battery BR2032 and a cable for connecting the analog inputs. M221 logic controllers have three types of integrated communication port, Ethernet, RS 232/RS 485 serial link and USB mini-B programming port. It enables the control of simple machines. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.

Lead time: in stock

Warranty: 12 months
Type of payment: T/T 100% Payment in Advance
Courier partners: DHL, UPS, FedEx 

Packing & Delivery

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging.

Related parts :

CompactCom B30
DeviceNet™ B30 Brick  AB6381
Profibus DPV1 B30 Brick AB6380

EtherCAT B30 Brick AB6385

EtherNet/IP™ 2 Port B30 Brick AB6384
Modbus TCP 2 Port B30 Brick AB6383
PROFINET IO 2 Port B30 Brick AB6382

Anybus CompactCom M30 MODULE

Questions? Call/Whatsapp +86-18030186862 or email saleszxtech@163.com

We specialize in purchasing and selling quality pre-owned mechanical parts, PLCs, motors, panel views, electrical components and other industrial surplus inventory. We stock a wide variety of items ranging from small parts to complete machines. Whether you are interested in selling or buying, we make it our mission to help customers have a quick, hassle-free experience.