Welcome to the world of smart home

0
Model No: AF65-30-11-14

ABB AF65-30-11-14 250-500V50/60HZ-DC Contactor

ABB AF65-30-11-14

250-500V50/60HZ-DC Contactor

Faster quote : saleszxtech1@163.com
Delivery :
EXW
minimum order :
1 piece
Supply Ability :
1000piece /
Stock Time :
2-3Day
Quantity :
add to cart
Contact Now

Dimensions

    • Product Net Width:

    • 67 mm

    • Product Net Depth / Length:

    • 111 mm

    • Product Net Height:

    • 125.5 mm

    • Product Net Weight:

    • 0.99 kg

Technical

    • Number of Main Contacts NO:

    • 3

    • Number of Main Contacts NC:

    • 0

    • Number of Auxiliary Contacts NO:

    • 1

    • Number of Auxiliary Contacts NC:

    • 1

    • Standards:

    • IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22

    • Rated Operational Voltage:

    • Auxiliary Circuit 690 V
      Main Circuit 690 V

    • Rated Frequency (f):

    • Auxiliary Circuit 50 / 60 Hz
      Control Circuit 50 / 60 Hz
      Main Circuit 50 / 60 Hz

    • Conventional Free-air Thermal Current (Ith):

    • acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A
      acc. to IEC 60947-5-1, Θ = 40 °C 16 A

    • Rated Operational Current AC-1 (Ie):

    • (690 V) 40 °C 105 A
      (690 V) 60 °C 90 A
      (690 V) 70 °C 80 A

    • Rated Operational Current AC-3 (Ie):

    • (415 V) 60 °C 65 A
      (440 V) 60 °C 65 A
      (500 V) 60 °C 55 A
      (690 V) 60 °C 39 A
      (380 / 400 V) 60 °C 65 A
      (220 / 230 / 240 V) 60 °C 65 A

    • Rated Operational Current AC-3e (Ie):

    • (415 V) 60 °C 65 A
      (440 V) 60 °C 65 A
      (500 V) 60 °C 55 A
      (690 V) 60 °C 39 A
      (380 / 400 V) 60 °C 65 A
      (220 / 230 / 240 V) 60 °C 65 A

    • Rated Operational Power AC-3 (Pe):

    • (400 V) 30 kW
      (415 V) 37 kW
      (440 V) 37 kW
      (500 V) 37 kW
      (690 V) 37 kW
      (380 / 400 V) 30 kW
      (220 / 230 / 240 V) 18.5 kW

    • Rated Operational Power AC-3e (Pe):

    • (415 V) 37 kW
      (440 V) 37 kW
      (500 V) 37 kW
      (690 V) 37 kW
      (380 / 400 V) 30 kW
      (220 / 230 / 240 V) 18.5 kW

    • Rated Operational Current AC-15 (Ie):

    • (500 V) 2 A
      (690 V) 2 A
      (24 / 127 V) 6 A
      (220 / 240 V) 4 A
      (400 / 440 V) 3 A

    • Rated Short-time Withstand Current Low Voltage (Icw):

    • at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 A
      at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A
      for 0.1 s 140 A
      for 1 s 100 A

    • Maximum Breaking Capacity:

    • cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 A
      cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A

    • Maximum Electrical Switching Frequency:

    • (AC-1) 600 cycles per hour
      (AC-15) 1200 cycles per hour
      (AC-2 / AC-4) 150 cycles per hour
      (AC-3) 1200 cycles per hour
      (DC-13) 900 cycles per hour

    • Rated Operational Current DC-1 (Ie):

    • (110 V) 2 Poles in Series, 40 °C 105 A
      (110 V) 2 Poles in Series, 60 °C 90 A
      (110 V) 2 Poles in Series, 70 °C 80 A
      (110 V) 3 Poles in Series, 40 °C 105 A
      (110 V) 3 Poles in Series, 60 °C 90 A
      (110 V) 3 Poles in Series, 70 °C 80 A
      (220 V) 3 Poles in Series, 40 °C 105 A
      (220 V) 3 Poles in Series, 60 °C 90 A
      (220 V) 3 Poles in Series, 70 °C 80 A
      (72 V) 1-Pole, 40 °C 105 A
      (72 V) 1-Pole, 60 °C 90 A
      (72 V) 1-Pole, 70 °C 80 A
      (72 V) 2 Poles in Series, 40 °C 105 A
      (72 V) 2 Poles in Series, 60 °C 90 A
      (72 V) 2 Poles in Series, 70 °C 80 A
      (72 V) 3 Poles in Series, 40 °C 105 A
      (72 V) 3 Poles in Series, 60 °C 90 A
      (72 V) 3 Poles in Series, 70 °C 80 A

    • Rated Operational Current DC-3 (Ie):

    • (110 V) 2 Poles in Series, 40 °C 105 A
      (110 V) 2 Poles in Series, 60 °C 90 A
      (110 V) 2 Poles in Series, 70 °C 80 A
      (110 V) 3 Poles in Series, 40 °C 105 A
      (110 V) 3 Poles in Series, 60 °C 90 A
      (110 V) 3 Poles in Series, 70 °C 80 A
      (220 V) 3 Poles in Series, 40 °C 105 A
      (220 V) 3 Poles in Series, 60 °C 90 A
      (220 V) 3 Poles in Series, 70 °C 80 A
      (72 V) 1-Pole, 40 °C 105 A
      (72 V) 1-Pole, 60 °C 90 A
      (72 V) 1-Pole, 70 °C 80 A
      (72 V) 2 Poles in Series, 40 °C 105 A
      (72 V) 2 Poles in Series, 60 °C 90 A
      (72 V) 2 Poles in Series, 70 °C 80 A
      (72 V) 3 Poles in Series, 40 °C 105 A
      (72 V) 3 Poles in Series, 60 °C 90 A
      (72 V) 3 Poles in Series, 70 °C 80 A

    • Rated Operational Current DC-5 (Ie):

    • (110 V) 2 Poles in Series, 40 °C 105 A
      (110 V) 2 Poles in Series, 60 °C 90 A
      (110 V) 2 Poles in Series, 70 °C 80 A
      (110 V) 3 Poles in Series, 40 °C 105 A
      (110 V) 3 Poles in Series, 60 °C 90 A
      (110 V) 3 Poles in Series, 70 °C 80 A
      (220 V) 3 Poles in Series, 40 °C 105 A
      (220 V) 3 Poles in Series, 60 °C 90 A
      (220 V) 3 Poles in Series, 70 °C 80 A
      (72 V) 1-Pole, 40 °C 105 A
      (72 V) 1-Pole, 60 °C 90 A
      (72 V) 1-Pole, 70 °C 80 A
      (72 V) 2 Poles in Series, 40 °C 105 A
      (72 V) 2 Poles in Series, 60 °C 90 A
      (72 V) 2 Poles in Series, 70 °C 80 A
      (72 V) 3 Poles in Series, 40 °C 105 A
      (72 V) 3 Poles in Series, 60 °C 90 A
      (72 V) 3 Poles in Series, 70 °C 80 A

    • Rated Operational Current DC-13 (Ie):

    • (24 V) 6 A / 144 W
      (48 V) 2.8 A / 134 W
      (72 V) 1 A / 72 W
      (110 V) 0.55 A / 60 W
      (125 V) 0.55 A / 69 W
      (220 V) 0.27 A / 60 W
      (250 V) 0.27 A / 68 W
      (400 V) 0.15 A / 60 W
      (500 V) 0.13 A / 65 W
      (600 V) 0.1 A / 60 W

    • Rated Insulation Voltage (Ui):

    • acc. to IEC 60947-4-1 690 V
      acc. to IEC 60947-5-1 690 V
      acc. to UL/CSA 600 V

    • Rated Impulse Withstand Voltage (Uimp):

    • 6 kV

    • Maximum Mechanical Switching Frequency:

    • 3600 cycles per hour

    • Rated Control Circuit Voltage (Uc):

    • 50 Hz 250 ... 500 V
      60 Hz 250 ... 500 V
      DC Operation 250 ... 500 V

    • Coil Consumption:

    • Average Holding Value 50 / 60 Hz 4 V·A
      Average Holding Value 50 Hz 4 V·A
      Average Holding Value 60 Hz 4 V·A
      Average Holding Value DC 2 W
      Average Holding Value, from Warm State 2 W

    • Operate Time:

    • Between Coil De-energization and NC Contact Closing 19 ... 105 ms
      Between Coil De-energization and NO Contact Opening 17 ... 100 ms
      Between Coil Energization and NC Contact Opening 38 ... 95 ms
      Between Coil Energization and NO Contact Closing 42 ... 100 ms

    • Mounting on DIN Rail:

    • TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
      TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

    • Mounting by Screws (not supplied):

    • 2 x M4 or 2 x M6 screws placed diagonally

    • Connecting Capacity Main Circuit:

    • Flexible with Ferrule 1/2x 4 ... 35 mm²
      Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²
      Rigid Stranded 1/2x 6 ... 35 mm²

    • Connecting Capacity Auxiliary Circuit:

    • Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
      Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
      Rigid 1/2x 1 ... 2.5 mm²

    • Connecting Capacity Control Circuit:

    • Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
      Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
      Rigid Solid 1/2x 1 ... 2.5 mm²
      Rigid Stranded 1/2x 1 ... 2.5 mm²

    • Wire Stripping Length:

    • Auxiliary Circuit 10 mm
      Control Circuit 10 mm
      Main Circuit 16 mm

    • Degree of Protection:

    • acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
      acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10

    • Terminal Type:

    • Screw Terminals

Technical UL/CSA

    • Maximum Operating Voltage UL/CSA:

    • Main Circuit 600 V

    • General Use Rating UL/CSA:

    • (600 V AC) 90 A

    • Horsepower Rating UL/CSA:

    • (120 V AC) Single Phase 5 hp
      (200 ... 208 V AC) Three Phase 20 hp
      (220 ... 240 V AC) Three Phase 25 hp
      (240 V AC) Single Phase 15 hp
      (440 ... 480 V AC) Three Phase 50 hp
      (550 ... 600 V AC) Three Phase 60 hp

    • Connecting Capacity Main Circuit UL/CSA:

    • Rigid Stranded 1/2x 10-2 AWG

    • Connecting Capacity Control Circuit UL/CSA:

    • Rigid Solid 1/2x 18-14 AWG
      Rigid Stranded 1/2x 18-14 AWG

    • Tightening Torque UL/CSA:

    • Auxiliary Circuit 11 in·lb
      Control Circuit 11 in·lb
      Main Circuit 35 in·lb

Lead time: in stock

Warranty: 12 months
Type of payment: T/T 100% Payment in Advance
Courier partners: DHL, UPS, FedEx 

Packing & Delivery

To better ensure the safety of your goods, professional, environmentally friendly, convenient and efficient packaging.

Questions? Call/Whatsapp +86-17750619597 or email saleszxtech1@163.com

We specialize in purchasing and selling quality pre-owned mechanical parts, PLCs, motors, panel views, electrical components and other industrial surplus inventory. We stock a wide variety of items ranging from small parts to complete machines. Whether you are interested in selling or buying, we make it our mission to help customers have a quick, hassle-free experience.